Keyboard shortcuts

Press ← or → to navigate between chapters

Press S or / to search in the book

Press ? to show this help

Press Esc to hide this help

Nuclear data

Transport needs nuclear data that FARIS does not ship: the files are large and their redistribution terms are not settled. You assemble a library once, from public sources, and FARIS records which library every run used, by the digests of its cross_sections.xml and its audit.

The two libraries

LibraryContentSizeUsed by
First (combined-fendl32-endfbvii1)22 FENDL-3.2 neutron nuclides and eight ENDF/B-VII.1 photon elements (H, Li, Be, F, Ti, Fe, Cu, W)smallthe recorded study; never modified
v2 (fendl32-endfbvii1-v2)every FENDL-3.2 neutron nuclide (193, one gap-filled from ENDF/B-VIII.1), photon data for all 61 elements in them, 20 ENDF/B-VIII.1 thermal-scattering tablesabout 9.4 GByour own designs; not yet the default

v2 covers the natural isotopes of every element in the common fusion materials: steels (SS316L, EUROFER97), Inconel 718, CuCrZr, tungsten and WC, V-4Cr-4Ti, TZM, concrete, helium, air, water, FLiBe, PbLi, B4C, the hydrides, the lithium ceramics, beryllium and Be12Ti, REBCO tape, Nb3Sn, NbTi, copper and epoxy insulation. Its thermal tables are H in H2O, D and O in D2O, Be metal, Be and O in BeO, Be, F and Li in FLiBe, graphite, H and Li in 7LiH, D and Li in 7LiD, Ca and H in CaH2, H and Zr in ZrH2, and H in polyethylene. ENDF/B-VIII.1 has no table for TiH2, natural-lithium hydride or oxygen in liquid water.

Things to know about v2:

  • Thermal tables apply only when a material declares them. They are ENDF/B-VIII.1 evaluations used with FENDL-3.2 neutron data; combining libraries this way is standard practice, and it is a stated assumption.
  • Most of the 9.4 GB is the thermal tables, which store up to 94 temperatures each; the H in H2O table alone is 2.6 GB. The neutron files are about 0.9 GB.

Sources

  • FENDL-3.2 neutron data in HDF5, from the OpenMC data-library page.
  • ENDF/B-VIII.1 in HDF5 (thermal tables and gap fill), OpenMC’s official build, from the same page.
  • ENDF/B-VII.1 photoatomic and atomic-relaxation sublibraries, from the NNDC download page, which publishes their MD5 checksums. FARIS converts them to HDF5 with OpenMC 0.15.3 and checks the MD5 values before converting.

Build v2

Download the sources above into a folder outside the FARIS source tree, then run, with the OpenMC 0.15.3 Python environment:

OPENMC_PY=/path/to/openmc-0.15.3/bin/python
"$OPENMC_PY" scripts/build_nuclear_data_v2.py \
  --fendl-dir /path/to/fendl-3.2-hdf5 \
  --endfb-viii-dir /path/to/endfb-viii.1-hdf5 \
  --photoatomic-zip /path/to/ENDF-B-VII.1-photoat.zip \
  --atomic-relaxation-zip /path/to/ENDF-B-VII.1-atomic_relax.zip \
  --first-provenance references/photon-library-provenance.json \
  --output-dir data/raw/fendl32-endfbvii1-v2 \
  --provenance-out my-v2-provenance.json
"$OPENMC_PY" integrations/openmc/audit_library.py \
  --cross-sections data/raw/fendl32-endfbvii1-v2/cross_sections.xml \
  --nuclide-set fusion-materials-v1 \
  --output my-v2-audit.json

The build downloads nothing and is deterministic. It refuses to replace an existing library unless given --force, and --force replaces only a folder it built itself. The audit confirms that OpenMC can read every file the material set needs; give its output to a run together with the library’s cross_sections.xml.

What the audit does not establish

The audit records file identity and readability. It does not qualify the nuclear data for a particular calculation, and it does not authenticate the FENDL-3.2 and ENDF/B-VIII.1 downloads; only the two ENDF/B-VII.1 archives are checked against published checksums. Thermal tables larger than 1 GiB are read at 294 K only, because loading every temperature needs several GB of memory; the audit record states the scope for each table.